FM-MP3 evo A4

Heavy Duty Three Segments Through Anchor

The FM-MP3 evo A4 is an anchor made of A4 stainless steel, which is placed into a drilled hole and anchored by torque-controlled expansion.

Marcação CE
ATE
Aço inoxidável
Fogo R120
Fix Calc

Detalhes do produto

Aplicação

Applications

  • Safety barriers
  • Fencing
  • Railings

Suitable for

  • Multiple use for non-structural applications on cracked and non-cracked concrete

Dados técnicos

Dimensões

Material

  • Steel
  • White zinc plated

Benefits

  • Universal metallic anchor even for hollow base materials
  • Single shell body with exclusive cone containing system
  • Accessories for all types of fixing requirements
  • Fire resistance R120

Product Dimensions Anchor Only

Table "Product Dimensions Anchor Only" cannot be displayed : no references available.

*Certified product when coupled with stainless steel A4-70 hex head screw DIN933 and stainless steel A4 washer DIN125-1 or ISO 7089.

Product Dimensions Hex Head Screw

Referência Product Reference Dimensions [ØxL] [mm] Max. fixture thickness [tfix] [mm] Hole  diameter [do] Min. hole depth [h1] Nominal embedment depth [hnom] Min. setting depth [hef] Hole diameter in fixing element [df] Min. fixture thickness [hmin] Thread length [Lv] Torque [Tinst] Qty per box Qty per outer box
7330101205000FM-MP3 evo A4M8x50101270504310100601550250
7330101506000M10x60201580605012100803025125
7330101808000M12x8020181008069141401005020100

** Not covered by CE certification 

Recommended loads / for single anchors / with no edge distances or spacings - ETA-09/0067

Table "Recommended loads / for single anchors / with no edge distances or spacings - ETA-09/0067" cannot be displayed : no references available.

1. The recommended loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s) and with a partial safety factor for actions of γF=1.4. The loading figures
are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10 mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per
ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile
stress within the concrete induced by external loads, anchors loads included).

Design capacities - single anchor - no edge distances

Referência Product Reference Dimensions [ØxL] [mm] Design capacity - Non-cracked concrete (3)
Tension - NRd (1) Shear - VRd (1-2) Bending moment MRd [Nm]
C20/25 [kN] C30/37 [kN] C40/50 [kN] C50/60 [kN] C20/25 [kN] C30/37 [kN] C40/50 [kN] C50/60 [kN]
7330101205000FM-MP3 evo A4M8x506.7---7.7---24
7330101506000FM-MP3 evo A4M10x608.9---9.7---48
7330101808000FM-MP3 evo A4M12x8013.9---18.6---84

1. The design loads loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

Recommended loads / for single anchors / with no edge distances or spacings - ETA-10/0074

Table "Recommended loads / for single anchors / with no edge distances or spacings - ETA-10/0074" cannot be displayed : no references available.

1. The recommended loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s) and with a partial safety factor for actions of γF=1.4. The loading figures
are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10 mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per
ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

Instalação

Instalação

Installation data

Referência Product Reference Dimensions [ØxL] [mm] Ø drilling hole [d0] [mm] Min. drill depth [h1] [mm] Ø drilling fixture [df] [mm] Installation torque [Tinst] [Nm] Embedment depth [hef] [mm] Min. support thickness [hmin] [mm]
7330101205000FM-MP3 evo A4M8x501270101543100
7330101506000FM-MP3 evo A4M10x601580123050100
7330101808000FM-MP3 evo A4M12x8018100145069140

** Not covered by CE certification 

Spacings and edge distances - ETA-09/0067

Table "Spacings and edge distances - ETA-09/0067" cannot be displayed : no references available.

Spacings and edge distances - ETA-10/0074

Table "Spacings and edge distances - ETA-10/0074" cannot be displayed : no references available.

Comprar online

No items available.

Contact

Simpson Strong-Tie França

Simpson Strong-Tie

ZAC des 4 Chemins
85400 Sainte-Gemme-la-Plaine
França